Mid-Week Connection (Initialization and Binding) with New UUID

The purpose of this test is to verify that the client system can:

  • recover undelivered business messages from the CME system during the mid-week initialization and binding
  • adjust the inbound and outbound sequence numbers as needed

 

  1. Select a SenderComp from the drop-down and select ASSIGN if a SenderComp is not already assigned.
  2. From the Contracts drop-down, select the desired contract if the contract is not already locked.
  3. Select the START TEST button.

Note: DO NOT select the START TEST button once the test is in progress.

Note: If a test is not proceeding to the next step, selecting the Refresh button ( ) below the test steps may resolve the issue.

Pre-Registered or On-Demand Format

Note: This test is used for both Pre-Registered and On-Demand formats. The image below shows the Pre-Registered format version of the test.

  • To run a Mid-Week Connection (Initialization and Binding) with New UUID test:
  1. Over an ilink connection, submit one Limit order for a selected outright instrument.
  2. Receive and process an Execution Report - Confirmation/Acknowledgement Execution Report - New Order message and then submit a Terminate message or disconnect the session.
  3. On the same segment, submit a Negotiate message with a new UUID.
  4. Receive and process a Negotiate Response message.
  5. Submit an Establish message to bind connection.
  6. Select Yes or No to indicate whether your system received and processed the Establishment Acknowledgment message.
  1. Submit a Retransmit Request message for the undelivered Execution Report.
  2. Select Yes or No to indicate whether your system received and processed the Retransmission message for the undelivered Execution Report.
  1. Submit a Sequence message.
  1. Receive and process a Sequence message.